Search results for: Listeria, 'real time' PCR Kit for detection of food pathogens
#36084091 // To Up
Comparison of DNA Extraction Methods for the Quantification of Listeria monocytogenes in Dairy Products by Real-Time Quantitative PCR>.
Listeria monocytogenes is a common foodborne pathogen affecting public health. Thus, detecting L. monocytogenes, even at low levels, in food matrices is essential. However, the current culture methods used for its detection and quantification are time consuming and difficult owing to background flora and interference by food matrices. DNA-based assays depend on DNA extraction and purification techniques. No optimal DNA extraction kit has been developed for analyzing L. monocytogenes in dairy products by real-time quantitative PCR (RT-qPCR). Therefore, in this study, we aimed to determine the efficiency of three DNA extraction kits for detecting L. monocytogenes in dairy products by RT-qPCR. We tested the efficiency of three commercial kits for DNA extraction from L. monocytogenes artificially inoculated in milk and dairy products. For the PrepSEQ rapid spin sample preparation kit and Exgene Cell SV mini, the limit of detection of was 100, 100, and 101 CFU/mL L. monocytogenes in milk, processed cheese, and infant formula, respectively, whereas that of the QIAamp DNA mini kit was 101, 103, and 102 CFU/mL, respectively. In addition, the Exgene Cell SV mini was better than the PrepSEQ rapid spin sample preparation kit for obtaining a standard curve for RT-qPCR of L. monocytogenes DNA in milk and dairy products, with a high correlation coefficient and amplification efficiency. The results of this study may be valuable for diagnostic laboratories and for developing an effective extraction method for processing food samples, such as dairy products, to subsequently detect and quantify L. monocytogenes by RT-qPCR.Eun Jeong Heo, Ha-Young Kim, Soo Hwan Suh, Jin San Moon
2476 related Products with: Comparison of DNA Extraction Methods for the Quantification of Listeria monocytogenes in Dairy Products by Real-Time Quantitative PCR>.
2525252525252525 1 G96 wells2525Related Pathways
Error loading info... Pleas try again later.
#22165012 // To Up
Evaluation of applied biosystems MicroSeq real-time PCR system for detection of Listeria monocytogenes in food. Performance Tested Method 011002.
Increasingly, more food companies are relying on molecular methods, such as PCR, for pathogen detection due to their improved simplicity, sensitivity, and rapid time to results. This report describes the validation of a new Real-Time PCR method to detect Listeria monocytogenes in nine different food matrixes. The complete system consists of the MicroSEQ L. monocytogenes Detection Kit, sample preparation, the Applied Biosystems 7500 Fast Real-Time PCR instrument, and RapidFinder Express software. Two sample preparation methods were validated: the PrepSEQ Nucleic Acid extraction kit and the PrepSEQ Rapid Spin sample preparation kit. The test method was compared to the ISO 11290-1 reference method using an unpaired-study design to detect L. monocytogenes in roast beef, cured bacon, lox (smoked salmon), lettuce, whole cow's milk, dry infant formula, ice cream, salad dressing, and mayonnaise. The MicroSEQ L. monocytogenes Detection Kit and the ISO 11290-1 reference method showed equivalent detection based on Chi-square analysis for all food matrixes when the samples were prepared using either of the two sample preparation methods. An independent validation confirmed these findings on smoked salmon and whole cow's milk. The MicroSEQ kit detected all 50 L. monocytogenes strains tested, and none of the 30 nontargeted bacteria strains.Robert S Tebbs, Priya Balachandran, Lily Y Wong, Patrick Zoder, Manohar R Furtado, Olga V Petrauskene, Yanxiang Cao
2962 related Products with: Evaluation of applied biosystems MicroSeq real-time PCR system for detection of Listeria monocytogenes in food. Performance Tested Method 011002.
252525252525252x96 well plate200 250 eaRelated Pathways
Error loading info... Pleas try again later.
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]