Search results for: AIV H9 Real_Time PCR Kit
#36731632 2023/01/31 To Up
Comparative assessment of lyophilized and wet reagents for the molecular detection of H5N1 high pathogenic avian influenza virus and H9N2 low pathogenic avian influenza virus.
Global surveillance for Avian Influenza Virus (AIV) in birds is essential for assessing public and animal health risks and real-time polymerase chain reaction (RT-qPCR) is among the official methods recommended by the World Organisation for Animal Health (WOAH) to confirm the presence of the virus in laboratory specimens. Yet, in low-resource setting laboratories, the detection of AIV can be hampered by the need to maintain a cold chain for wet reagents. In such cases, alternatives should be ready to maximize surveillance capacities and mining of AIV. Therefore, we compared two lyophilized RT-qPCR reagents (1st - 5 × CAPITAL™ 1-Step qRT-PCR Probe Reagent, lyophilized kit, and 2nd - Qscript lyo 1-step-kit) to the WOAH recommended protocol by Nagy et al., 2020 using QuantiTect Probe RT-PCR-kit as wet reagent. The comparative study panel comprised 102 RNA samples from two AIV subtypes, i.e. H5 and H9 subtypes. Despite that the wet reagent exhibited the lowest limit of detection (LOD) compared to the two lyophilized reagents, the inter-assay agreement was substantial between the 1st lyophilized reagent and the comparator with 95.1% of shared positive results. Cohen's-kappa was fair between the 2nd lyophilized reagent and the comparator with 75.5% of shared positive results. Agreement using the statistical test Bland-Altman was good for samples with Cq-values < 25 for all reagents, revealing discrepancies when the viral load is low. This trend was especially evident while using the 2nd lyophilized reagent. Similar trends were obtained using the same lyophilized reagents but following the protocol by Heine et al., 2015 with AgPath-ID™ One-Step RT-PCR as a comparator, showing that Cq-values increase using lyophilized reagents but correlate strongly with the wet reagent. Further, inter-assay agreement between reagents improved when the protocol from Heine et al., 2015 was applied, suggesting a higher resilience to chemistry changes allowing easier reagents interchangeability.Agathe Auer, Valentina Panzarin, Isabella Monne, Marika Crimaudo, Angelique Angot, Morgane Gourlaouen, Charles E Lamien, Giovanni Cattoli
2133 related Products with: Comparative assessment of lyophilized and wet reagents for the molecular detection of H5N1 high pathogenic avian influenza virus and H9N2 low pathogenic avian influenza virus.
2525252510050 50 50 96T1. Set50 100Related Pathways
#24772890 // To Up
[Rapid detection of novel avian influenza virus subtype H7N9 by multiplex real-time RT-PCR].
In order to develop a rapid detection kit for novel avian influenza virus (AIV) subtype H7N9, two sets of specific primers and probes were designed based on the nucleotide sequences of hemagglutinin antigen (HA) and neuraminidase antigen (NA) of novel H7N9 virus (2013) available in GenBank to establish the method of TaqMan probe-based multiplex real-time RT-PCR for rapid detection of AIV subtype H7N9. The primer and probe of HA were for all H7 subtype AIVs, while the primer and probe of NA were only for novel N9 subtype AIVs. The results showed that this method had high sensitivity and specificity. This method was applicable to the testing of positive standard sample with a minimum concentration of 10 copies/microL; it not only distinguished H7 subtype from H1, H3, H5, H6, and H9 subtypes, but also distinguished novel N9 subtype from traditional N9 subtype. A total of 2700 samples from Zhuhai, China were tested by this method, and the results were as expected. For the advantages of sensitivity and specificity, the method holds promise for wide application.Bao-Zheng Luo, Qiu-Hua Mo, Ru-Shu Li, Qing-Ru Bo, Hai-Nie Xu, Cai-Hua Sha, Xiu-Yun Liao
1416 related Products with: [Rapid detection of novel avian influenza virus subtype H7N9 by multiplex real-time RT-PCR].
252525252525252525252525Related Pathways
Contact Us:
Belgium
Voortstraat 49, 1910 Kampenhout BELGIUM
Tel 0032 16 58 90 45 Fax 0032 16 50 90 45
[email protected]
France
9, rue Lagrange, 75005 Paris
Tel 01 43 25 01 50 Fax 01 43 25 01 60
[email protected]
Germany
GENTAUR GmbH
Marienbongard 20
52062 Aachen Deutschland
Tel 0241 40 08 90 86 Fax 0241 55 91 05 36
[email protected]
United Kingdom
GENTAUR Ltd.
Howard Frank Turnberry House
1404-1410 High Road
Whetstone London N20 9BH
Tel 020 3393 8531 Fax 020 8445 9411
[email protected]
Also in
Luxembourg +35220880274
Schweiz Züri +41435006251
Danmark +4569918806
Österreich +43720880899
Česká republika Praha +420246019719
Ireland Dublin +35316526556
Norge Oslo +4721031366
Finland Helsset +358942419041
Sverige Stockholm +46852503438
Ελλάς Αθήνα +302111768494
Magyarország Budapest +3619980547
Poland
GENTAUR Poland Sp. z o.o.
ul. Grunwaldzka 88/A m.2
81-771 Sopot, Poland
Tel 058 710 33 44
Fax 058 710 33 48
[email protected]
skype gentaurpoland
Nederland
GENTAUR Nederland BV
Kuiper 1
5521 DG Eersel Nederland
Tel 0208-080893 Fax 0497-517897
[email protected]
Italy
GENTAUR SRL
IVA IT03841300167
Piazza Giacomo Matteotti, 6, 24122 Bergamo
Tel 02 36 00 65 93 Fax 02 36 00 65 94
[email protected]
Spain
GENTAUR Spain
Tel 0911876558
[email protected]
Bulgaria
GENTAUR Bulgaria
53 Iskar Str. 1191 Kokalyane, Sofia
Sofia 1000
Tel 0035924682280
Fax 0035929830072
[email protected]